SC-T85 Benchtop High-Precision Spectrophotometer

Benchtop spectrophotometer for laboratory colour management. Repeatability dE*ab <= 0.018 with a 154 mm integrating sphere.

Request a Quote

Benchtop high-precision spectrophotometer for laboratory-grade colour management.

  • Repeatability ΔE*ab ≤ 0.018
  • 256-pixel dual-array CMOS sensor
  • Full-spectrum LED plus UV

The SC-T85 carries forward our core spectroscopic technology and supports both D/8 and D/0 optical paths, combining laboratory-grade accuracy with wide sample adaptability — the benchmark for benchtop colour management.

It is fitted with a 154 mm integrating sphere and a 256-pixel dual-array CMOS image sensor. Repeatability is held within ΔE*ab 0.018 and inter-instrument agreement within ΔE*ab 0.24. It supports reflectance and transmittance as well as SCI/SCE measurement, covering opaque, transparent, semi-transparent and fluorescent samples. Widely used in plastics and electronics, chemical coatings, printing inks, textile dyeing, automotive electronics, medical analysis, cosmetics and food analysis, as well as in research institutes and laboratory pharmaceutical analysis.

Features

  1. High-performance dual-array image sensor — a 256-pixel dual-array CMOS sensor with high sensitivity delivers high accuracy and repeatability across a wide spectral response range.
  2. Comprehensive measurement — the internationally accepted D/8 and D/0 dual optical path structure supports SCI/SCE and reflectance/transmittance measurement for opaque, transparent, semi-transparent and fluorescent samples.
  3. Combined LED and UV light source — full-spectrum LED plus UV covering 360–780 nm, including UV, 400 nm cut-off, 420 nm cut-off and 460 nm cut-off sources, giving sufficient spectral distribution and more professional UV testing.
  4. Multiple measurement orientations — side, upward and downward measurement (the last with an optional inverted bracket), which greatly improves convenience and flexibility.
  5. Open transmission compartment — measures transmission samples up to 54 mm thick, so even large samples are handled easily.
  6. Automatic aperture recognition — four apertures of 25.4 mm, 15 mm, 8 mm and 4 mm. The user configures the aperture and lens position as needed, which is both flexible and intelligent.
  7. Rich chromaticity indices — besides common colour metrics, it offers haze, transmittance, petroleum colour scale (ASTM D1500), yellowness, whiteness, platinum-cobalt index, Gardner index, Saybolt index, blackness and hue.
  8. Ten colour spaces and 41 observation light sources — CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, DIN Lab99 and Munsell, plus D65, A, C, D50, D55, D75, F1, F2 (CWF) and others, 41 in total (some via PC software).
  9. Live camera viewfinder — a built-in camera locates the measuring point so you can confirm the target centre, improving efficiency and accuracy.
  10. Good repeatability and inter-instrument agreement — repeatability ΔE*ab ≤ 0.018 and inter-instrument agreement ΔE*ab ≤ 0.24 keep data consistent across units, making sample data transfer between partners straightforward.
  11. Independent light source detector — monitors the light source continuously, ensuring a reliable source and dependable test data.
  12. Practical, thoughtful design — a damped clamp protects the sample, and a spring-loaded drawer stores accessories and small samples.
  13. Colour management software for extended functions — SQCX quality management software suits quality monitoring and colour data management across industries. It digitises colour, compares colour differences, generates test reports and provides measurement data in multiple colour spaces for customised colour management.

Technical Parameters

  • Reflectance: D/8 (diffuse illumination, 8 degree viewing), SCI/SCE measurement, including UV / excluding UV
  • Transmittance: D/0 (diffuse illumination, 0 degree viewing), SCI/SCE measurement, including UV / excluding UV, haze (ASTM D1003)
  • Standards: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7, JIS Z8722 condition C
  • Widely used in plastics and electronics, paint and ink, textile dyeing and printing, automotive electronics, medical analysis and similar industries
  • 7 inch independent rotatable touch screen, 32 GB storage, live camera viewfinder
  • Side, upward and downward measurement (with accessories) for multiple orientations
  • Open transmission compartment for samples up to 54 mm thick
  • Automatic temperature and humidity compensation
  • 360–780 nm combined LED source including UV, 400 nm cut-off, 420 nm cut-off and 460 nm cut-off sources
  • Reflectance apertures: XLAV 25.4 mm / 30 mm, LAV 15 mm / 18 mm, MAV 8 mm / 10 mm, SAV 4 mm / 6 mm
  • Transmittance: 25.4 mm (sample height unrestricted, thickness up to 54 mm)
  • Note: apertures are recognised automatically when switched; the customer configures aperture and lens position as required
Type Configuration
Model SC-T85 (LED light source)
Illumination Method Reflectance: D/8 (diffuse illumination, 8 degree viewing), SCI/SCE, including/excluding UV. Transmittance: D/0 (diffuse illumination, 0 degree viewing), SCI/SCE, including/excluding UV, haze (ASTM D1003) Complies with: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724/1, ASTM E1164, DIN 5033 Part 7, JIS Z8722 Condition C
Features 1. Widely used in plastics and electronics, paint and ink, textile dyeing and printing, printing, automotive electronics and medical analysis. 2. 7 inch independent rotatable touch screen, 32 GB storage, live camera viewfinder 3. Side-facing, upward-facing and downward-facing measurement (with accessories) for multiple sample orientations. 4. Open transmission compartment accepts samples up to 54 mm thick. 5. Automatic temperature and humidity compensation.
Integrating Sphere Size Φ154mm
Illumination Source 360-780 nm combined LED source including UV, 400 nm cut-off, 420 nm cut-off and 460 nm cut-off
Spectral Method Concave grating
Sensor 256-pixel dual-array CMOS image sensor
Measuring Wavelength Range 360~780nm
Wavelength Interval 10nm
Half Bandwidth 5nm
Reflectance Measuring Range 0~200%
Reflectance Resolution 0.01
Measuring Aperture Reflectance: XLAV 25.4 mm / 30 mm; LAV 15 mm / 18 mm; MAV 8 mm / 10 mm; SAV 4 mm / 6 mm Transmission: Φ25.4 mm (no limit on sample height, maximum thickness 54 mm). Notes: 1. Aperture is identified automatically when switched; 2. Aperture and lens position can be configured to suit the application
Measurement Mode Reflectance SCI/SCE, transmittance SCI/SCE
Colour Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,Munsell,s-RGB,HunterLab,βxy,DIN Lab99
Colour Difference Formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,DINΔE99,ΔE(Hunter),ΔE*CH
Other Chromaticity Indices Spectral reflectance; WI (ASTM E313, CIE/ISO, AATCC, Hunter, Taube, Berger Stensby);YI(ASTM D1925,ASTM E313); ISO brightness; R457; metamerism index Mt; staining fastness; colour change fastness; colour strength; opacity; APHA/Hazen/Pt-Co (platinum-cobalt index); Gardner index; 555 colour-tone classification; haze and transmittance (ASTM D1003); Saybolt index; ASTM D1500 colour scale; 8-degree gloss; blackness (My, dM); colour density CMYK (A, T, E, M); Tint; colour density; pharmacopoeia (China, Europe, US); EBC (beer colour); ICUMSA colour (sugar colour) (some functions available through PC software)
Observer Angle 2°/10°
Type Configuration
Observer Illuminants D65, A, C, D50, D55, D75, F1 to F12, CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, custom light sources available (41 in total, some via PC software)
Display Spectral graph/data, sample chromaticity, colour difference value/graph, chromaticity diagram, colour simulation, pass/fail result, colour deviation, colour assessment, haze, liquid colour
Measuring Time Approx. 2.0 s (approx. 4 s for simultaneous SCI/SCE)
Repeatability Reflectance chromaticity: 25.4 mm/SCI, ΔE*ab within 0.018 (standard deviation of 30 measurements on the white tile at 5 s intervals after warm-up calibration). Spectral reflectance/transmittance: ≤0.1%
Inter-instrument Agreement 25.4 mm/SCI, ΔE*ab within 0.24 (average of BCRA Series II 12 tiles)
Dimensions L x W x H = 440 x 248 x 283 mm
Weight Approx. 13.5 kg
Power Supply DC 24 V, 3 A adapter
Light Source Life Over 3 million measurements in 5 years
Display 7 inch independent rotatable touch screen
Interface USB, Bluetooth 5.0
Stored Data 32 GB storage, over 100,000 records (SCI/SCE counts as one record)
Language Simplified Chinese, Traditional Chinese, English (German, French, Spanish, Russian, Japanese, Thai, Korean, Polish and Portuguese can be customised)
Operating Temperature Range 0~40℃(32~104°F)
Storage Temperature Range -20~50℃(-4~122°F)
Standard Accessories Power adapter, manual, quality management software (USB drive), data cable, standard calibration plate, black calibration box, transmission black baffle, sample holder, 25.4 / 15 / 8 / 4 mm apertures, transmission test fixture assembly, cuvettes
Optional Accessories Inverted bracket, petri dish, 4 mm micro-aperture transmission fixture, film fixture
Note: Test reports are printed through a network printer connected to a PC or tablet. Subject to change without notice
ΔE*ab ≤ 0.018, outstanding repeatability 154 mm integrating sphere
256-pixel dual-array CMOS 360-780 nm full-spectrum LED + UV